The characteristic parameter table of
BCK series power-supply-transformer ¡¡¡¡

BCK-50 |

BCK-19 |
¡¡
Items |
BCK-50 |
BCK-19 |
Conditions |
Note |
Measuring Terminal |
Standard |
Measuring Terminal |
Standard |
Inductance |
(6)-(2) |
89¦ÌH÷10% |
(4)-(5) |
6 mH÷20% |
f=10KKZ Ta=20÷5¡æ f=1KHZ |
WK-4225
LCK bridge |
Leakage Lnductance |
(2-3) - (6-7) Short
(10¡¢ 12¡¢13¡¢14¡¢ 15¡¢16¡¢17¡¢ 18¡¢19¡¢20¡¢ 21¡¢22) |
4.5¦ÌH max |
(4)-(5)¡¢ (7)-(9) |
¡Ü0.5mH |
DC Resisange |
(6)-(2) |
37.6m¦¸max |
(4)-(5) |
6.7¦¸ max |
(7)-(3) |
53.5m¦¸max |
(12)-(10) |
10.1m¦¸max |
(1)-(2) |
2.5¦¸ max |
(13)-(14) |
35.2m¦¸max |
(15)-(16) |
12.4m¦¸max |
(9)-(7) |
175m¦¸max |
(17)-(18) |
12.4m¦¸max |
(19)-(20) |
23.4m¦¸max |
¡¡ |
¡¡ |
(21)-(22) |
142m¦¸max |
Dielectric Strength |
(2)(3)-(12)(13) (15)(17)(19) (21)
core |
No Breakdown |
pri - sec pri - sec |
No Breakdown |
AC 3KV 50HZ 1mA 1minute |
CJ2670 Testing equipment or
equialence |
Sec - core |
AC 1.5KV 50HZ 1mA
1minute |
Pri - pri |
Turns ratio |
(6)-(2) |
1000mV(REF) |
(5)-(4) |
100mV (REF) |
f=10KKZ |
2L-B CJ670 Testing equipment or
equialence |
(7)-(3) |
1000mV÷2% |
(1)-(2) |
121mV÷3% |
(12)-(10) |
104mV÷2% |
(9)-(7) |
122÷5% |
(13)-(14) |
292mV÷2% |
¡¡ |
¡¡ |
(15)-(16) |
125mV÷2% |
¡¡ |
¡¡ |
(17)-(18) |
125mV÷2% |
¡¡ |
¡¡ |
(19)-(20) |
167mV÷2% |
¡¡ |
¡¡ |
(21)-(22) |
1375mV÷2% |
¡¡ |
¡¡ |
Insulation Resistance |
¡¡ |
¡¡ |
¡¡ |
¡¡ |
DC 500V |
RCJ-3 Testing equipment or
equialence | |