BCK series power switch transformer¡¡

¡¡¡¡¡¡

BCK-40

BCK-40

bck03.jpg (4675 bytes)

BCK-42

The characteristic parameter table of

BCK series power-supply-transformer

Items BCK-40 BCK-42 Conditions Note
Measuring places Standard Measuring places Standard
Inductance (7)-(5) 330¦ÌH÷10% (11)-(14) 330¦ÌH÷10% f=10KKZ
Ta=20÷5
¡æ
f=1KHZ
WK-4225 LCK
bridge
Leakage
Lnductance
(7)-(5)
Short (10
¡¢11¡¢12¡¢13¡¢14¡¢15¡¢16)
6¦ÌH max (11) - (14)
Short sec
10¦ÌH max
DC Resisange (5)-(7) 181m¦¸ max (11)-(14) 278.6m¦¸max
(1)-(2) 342m¦¸ max (10)-(13) 44m¦¸max
(4)-(3) 94m¦¸ max (12)-(13) 17m¦¸max
(10)-(12) 385m¦¸ max (3)-(4) 238m¦¸max
(13)-(14) 42m¦¸ max (5)-(4) 24.5m¦¸max
(15)-(16) 50m¦¸ max (1)-(2) 40m¦¸max
¡¡ ¡¡ (16)-(1) 37m¦¸max
¡¡ ¡¡ (7)-(8) 40m¦¸max
¡¡ ¡¡ (6)-(7) 47.3m¦¸max
¡¡ ¡¡ (9)-(4) 37.3m¦¸max
Dielectric
Strength
(2)(3)(5)-(12)
(13)(15)
No
Breakdown
2.5kv
pri - sec
pri - sec
No
Breakdown
AC 3KV 50HZ
1mA 1minute
CJ2670 Testing equipment or equialence
(2)-(3) Sec - core
(2)-(5) Pri - pri AC 1.5KV 50HZ
1mA 1minute
(3)-(5) Sec - sec
Turns ratio (5)-(7) 100mV(REF) (11)-(14) 1000mV(REF) f=10KKZ 2L-B CJ670 Testing equipment or equialence
(7)-(6) 500mV÷2% (10)-(13) 166.6mV÷5%
(4)-(3) 83mV÷2% (12)-(13) 47.6mV÷5%
(12)-(10) 333mV÷2% (3)-(4) 904.7mV÷5%
(12)-(11) 1125mV÷2% (5)-(4) 71.42mV÷5%
(14)-(13) 562mV÷2% (1)-(2) 119mV÷5%
(16)-(15) 125mV÷2% (16)-(1) 107.1mV÷5%
(2)-(1) 145mV÷2% (7)-(8) 119mV÷5%
¡¡ ¡¡ (6)-(7) 142.8mV÷5%
¡¡ ¡¡ (9)-(4) 95.23mV÷5%
Insulation
Resistance
(1)(3)(5)-(10)(13)(15)
(1)(3)(5)(10)(13)(15)- Core
100m¦¸
min
¡¡ ¡¡ DC 500V RCJ-3 Testing equipment or equialence

 

 

                  