The drawing transformer for color TV-set﹛﹛

bct_01.jpg (2308 bytes)

BCT-001

bct_03.jpg (2413 bytes)

BCT-002

bct_02.jpg (2009 bytes)

BCT-003

﹛﹛

NO Items BCT-001 BCT-002 BCT-003
Measuring places Standards and conditions Measuring places Standards and conditions Measuring places Standards and conditions
1 Inductance (1)and(3) 150mH
IDC=40mA
(1)and(2) 19.2-28.8mH (1)and(2) 820-1150mH
380-550
H
(3)and(4) 141-212H (3)and(4)
2 Insulation resistance   winding and winding 100M次  
winding and core DC 500V
3 DC copper Resistance (1)and(3) 78-117 (1)and(2) 6.08-9.12 (1)and(2) 65.6-94.4
(4)and(6) 0.34-0.44 (3)and(4) 106-160m (3)and(4) 0.162-0.238
4 Dielectric strength AC1.5mA/minute winding and winding not breakdown AC1.5mA/minute
AC1.5mA/minute winding and core not breakdown AC1.5mA/minute

 